MH 3 Beam user manual 11
AC power
Read Safety information on page 5 before connecting the fixture
to AC mains power.
For protection from electric shock, the fixture must be grounded
(earthed). The power distribution circuit must be equipped with a
fuse or circuit breaker and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the
fixture with power must be located near the fixture and easily
accessible so that the fixtures can easily be disconnected from
power.
Do not insert or remove live Neutrik PowerCon connectors to
apply or cut power, as this may cause arcing at the terminals
that will damage the connectors.
Do not use an external dimming system to supply power to the
fixture, as this may cause damage to the fixture that is not
covered by the product warranty.
Always unlock the pan and tilt locks on the head yoke before
turning the fixture on.
Connect only a Neutrik PowerCon cable connector to the power input socket.
The power input cable must be rated 20 A minimum, have three conductors
1.5 mm² (16 AWG) minimum conductor size and an outer cable diameter of 5 -
15 mm (0.2 - 0.6 in.). Cable must be hard usage type (SJT or equivalent) and
heat-resistant to 90° C (194° F) minimum. In the EU the cable must be HAR
approved or equivalent.
The fixture can be hard-wired to a building electrical installation if you want to
install it permanently, or a mains plug (not supplied) that is suitable for the local
power outlets can be installed on the power cable.
The fixture has an auto-ranging power supply that accepts AC mains power at
100V~240V, 50/60 Hz. Do not apply AC mains power to the fixture at any other
voltage than this.